Skip to main content

Table 2 Effects of UV radiation on three indicator bacteria in two different semi-synthetic metal working fluids (MWFs). Values of initial and final viable counts represent mean of six replicates (n = 6)

From: Determination of the effectiveness of UV radiation as a means of disinfection of metalworking fluids

Bacteria

UV lamp intensity (μW/cm2)

MWF samplea

Condition

Initial viable count (CFU/mL)

Final viable count (CFU/mL)

Exposure time (in h)

Death rate (k, h−1)

P. fluorescens

38

MWF-A

Staticb

3.9(±0.05) × 107

1.92 (±0.04) × 107

0.25

−4.43

P. fluorescens

192

MWF-A

Static

5.3(±0.05) × 107

1.4 (±0.02) × 107

0.16

−8.32

P. fluorescens

192

MWF-B

Mixing

5.35(±0.2) × 107

6.4 (±0.01) × 105

0.03

−27.70

P. oleovorans subsp. lubricantis

192

MWF-B

Mixing

2.5(±0.005) × 107

2.73 (±0.01) × 105

0.03

−28.24

M. chelonae

192

MWF-B

Mixing

3.1(±0.1) × 104

5.50 (±0.2) × 103

0.03

−10.81

  1. aUnused 5 % diluted MWF from two different industries were used
  2. bApproximate laminar flow condition